BARIX Instreamer Manual do Utilizador Página 13

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 39
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 12
Technical Documentation “Instreamer “ - V4.03 - 24th October 2013
Element Description CGI command SERIAL, TCP or UDP command
Not all commands are changeable on the fly, for example
changing the TCP ports will have no affect. As a general rule
if there is already a separate command to perform the
change, e.g Volume control then QUIETCONFIG will not
work.
If you are not sure please ask Barix for advice.
STRING2SERIAL Sends a string to the serial port. Neither a zero terminator nor
a CR nor a LF will be added to the end of the string. Zero
character and ampersand (&) are impossible to send this way.
S=... 0x53 0x3D...0x00 (S=... )
SENDTCPSTRING Sends the attached string through the TCP interface. The
answer is the string itself.
T=… 0x53 0x3D (T=… )
VOLUME00
VOLUME01
---
VOLUME20
Set the volume for the headset
Set minimal volume level (volume off).
Set volume level 1.
Set maximal volume level.
Corresponding values sent to the codec for 0..20:
0, 76, 80, 84, 88, 92, 96, 99, 102, 106, 108, 110, 112, 114,
116, 118, 120, 124, 125, 126, 127
One step is showed as 5%. The level 0 equals the 0%.
v=0
v=1
---
v=20
0x76 0x3D 0x30 0x00 (v=0 )
0x76 0x3D 0x31 0x00 (v=1 )
---
0x76 0x3D 0x32 0x30 0x00 (v=20 )
13 Software Application Interface Software Application Interface 13