Barix Instreamer User Manual Version 01.03
Page 11
7.6 Control settings
These settings adjust the control port properties.
UDP command port
Defines the port where the device will receive commands
via UDP. To disable set this port number to
"0"
.
TCP command port
Defines the port where the device will receive commands
via TCP. To disable set this port number to
"0"
.
Web server port
Defines the port where the webserver of the Barix
Instreamer can be reached. If set to
"0"
the default HTTP
port (80) is used.
7.7 Serial settings
These settings adjust the serial port, local port and serial
gateway properties.
Baud rate
Select the serial transmission speed (
"300"
to
"115200"
Baud).
Data bits
Select
"7"
or
"8"
data bits.
Parity
Select
"no"
,
"even"
or
"odd"
parity.
Stop bits
Select
"1"
or
"2"
stop bits.
Flow control
Select the type of flow control:
"none"
,
"Software
(XON/XOFF)"
or
"Hardware (RTS/CTS)"
.
Local port
Defines the port on which the serial port can be accessed
for serial gateway application. Only when "Local port" is set
to
"0"
the serial port can be used as a command interface.
If the active serial gateway is enabled and the "Local port" is
set to a value then this will be the source port of the TCP
connection. On
"0"
a random source port is used.
Destination IP
To have this Barix Instreamer actively establish a serial
gateway select the destination IP address to the device
where the serial data will be transmitted to (and received
from).
Select
"0.0.0.0"
when the serial port is only used local.
Destination port
Defines the port for the active serial gateway function (see
destination IP).
Notes
Both settings, "Destination IP" and "Destination port" have
to be set to enable the gateway function.
When Serial Gateway is activated the serial port cannot be
used as a command interface. This also applies for the
device on the other side of the "Serial Gateway".
To establish a "Serial Gateway" between two devices only
one device has to be activated. In other words: Only one
device will need a Gateway destination IP and Port set.
On power up the active device will connect to the selected
device and will try to reconnect automatically in case of a
lost connection. This allows you to establish a serial
connection between the attached devices on each side over
LAN or WAN.
Comentários a estes Manuais