7.8 Security settings
These settings can be used to secure the access to the
device on different levels. The status is shown next to each
password (set or not set). Access is free for levels without
a password (default setting).
Telnet / Serial configuration
Enter up to 7 characters to secure the access to the Telnet
and Serial configuration. Without a valid password the
network configuration cannot be changed.
Enter 8 characters to erase the current key.
Save configuration
Enter up to 24 characters to secure the saving of the
device configuration (Clicking the "Apply" button).
Without a valid password the device configuration cannot
be saved! Enter 25 characters to erase the current key.
Save configuration password usage
When the password is set the user has to type in the
password in the "Save Config Password field" before hitting
the "Apply" button.
Without a valid password a warning will be displayed and
the changes don't save.
View configuration
Enter up to 24 characters to secure the viewing of the
device configuration (Clicking the "Config" button).
Without a valid password the device configuration cannot
be viewed! Enter 25 characters to erase the current key.
View configuration password usage
When the password is set the user clicking on the "Config"
button has to type in the password into the password field
of the pop up window (the user name does not matter).
Only one user can log in at a time. Further connections will
be refused while one user is logged in.
To log out click on the "Logout" link next to the "HOME"
icon in the menu bar.
Please hit your browser’s Reload button if the "Logout" link
is not visible while logged in.
Control / Command
Enter up to 24 characters to secure the access to all
control and command interfaces (WEB/CGI, Serial, TCP
and UDP). Without a valid password the device cannot be
controlled. Enter 25 characters to erase the current key.
Note
This security option should be used very carefully and is
intended for advanced users only. Since the CGI commands
used in the web interface do not make use of passwords,
setting this password would disable any control of the
device using a browser.
Level 4 to 6 (User)
Enter up to 24 characters to secure the access to
customized web pages in 3 levels. Intended for advanced
users only, for details see the Barix Instreamer Technical
Documentation. Without a valid password these user web
pages cannot be viewed. Enter 25 characters to erase the
current key.