User Manual “Instreamer“ - V4.03 - 24th October 2013
RS-232
Status of the hardware flow control signals of the
device's RS-232 iterface. The signals can be used
as a control input or output to control the device or
an attached equipment.
CTS in
Displays the status of the hardware CTS input
signal:
- grey box = Inactive
- green box = Active
Click the
"set"
button to emulate CTS being
activated.
Click the
"clear"
button to emulate CTS being
deactivated.
Note: the emulated input is not displayed on the
status page.
RTS out
Displays the status of the hardware RTS output
signal:
- grey box = Inactive
- green box = Active
Click the
"set"
button to activate the RTS signal.
Click the
"clear"
button to deactivate the RTS signal.
Contact inputs
Displays status of the eight digital contact closure
inputs (if available on the hardware):
- grey box = idle
- green box = Active
- crossed box = input not available on hardware
BARIX AG | 28. Jan. 2014 | Device Status and Control | 17 /63