User Manual “Instreamer“ - V4.03 - 24th October 2013
TCP Connection address
If 0.0.0.0, a listening command port is opened.
Otherwise a TCP connection is actively attempted at
the given address and port. If the connection fails, it
is reattempted every minute. Default:0.0.0.0
SNMP SETTINGS
SNMP traps are configured in this parameter group.
The traps are sent to the “Trap Target IP Address”.
The Standard Cold Start trap is sent on re-boot.
Two additional specific traps for left and right Audio
levels can be configure. The traps are triggered
according to specific audio values as described
below. Note that audio levels can only be monitored
for analogue audio inputs.
Trap Target IP Address
Enter the IP address of the SNMP trap destination.
Low Audio Level
Define the low audio level for the trap which will be
generated as soon as the audio level goes below
this value (and the “Silence timeout” has expired).
High Audio Level
Define the high audio level for the trap which will be
generated as soon as the audio level goes above
this value.
Trap Repeat
Define the SNMP trap repeat interval. The trap is
repeated if the audio level values are still out of
range.
Silence Timeout
Define the time interval for sending a trap after the
low audio level is detected.