BARIX Instreamer Manual do Utilizador Página 34

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 63
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 33
User Manual “Instreamer“ - V4.03 - 24th October 2013
Post Trigger Play
Post Trigger Play is only used when Streaming
mode is set to send on Level.
Post Trigger Play can be adjusted to prevent a cut
off when audio should be sent longer than detected.
It defines the amount of time that the device will
continue streaming after the actual trigger has been
cleared.
Contact Closure
Contact Closure is only used when Streaming mode
is set to send on I/O.
Defines the contact closure input (GPI) that controls
the device streaming in
"send on I/O"
. Select the
polarity in
"Input Polarity"
.
Input Polarity
Input Polarity is only used when Streaming mode is
set to send on I/O.
Selects the contact closure event that triggers the
streaming in
"send on I/O"
mode.
"active closed"
causes the device to stream when the selected
contact is closed.
"active open"
causes the device
to stream when the selected contact is open.
Used to select whether the device streams when the
selected control GPI is in the open or closed state.
Send Contact Closure Information
The current state of the device's GPI is inserted into
RTP and Shoutcast streams. (This also applies to
the BRTP connection type which uses an RTP
stream). This feature is compatible with Streaming
Client v02.10 and later.
34 /63 BARIX AG | 28. Jan. 2014 | Device Configuration
Vista de página 33